Part Number: NT10-0519-L06-2
NT10-0519-L06-2
Details & Specifications

DescriptionN Type Clamp Jack, Compression Fixing
To Fit Cable TypesLBC400, LBC400 ExtraFlex, LBC400 LSZH, RA519
Fixing MethodClamp
BodyBrass, Nickel Plated
ContactBrass, Gold Plated
DielectricPTFE
BacknutBrass, Nickel Plated
GrommetSilicone Rubber
Top HatBrass, Nickel Plated
WasherBrass, Nickel Plated
Cable RetentionEqual to breaking strain of cable
Dielectric Withstanding2500 Volts RMS Maximum
Durability500 mating cycles
Impedance50 ohms
Max. Frequency11 GHz
Temperature Range-65 to +165 degrees C
Working Voltage1500 Volts RMS Maximum


Assembly Instructions
Strip DimensionsA=9mm, B=2mm, C=5.5mm


1) Slide the Back Nut (BN), Rear Washer (RW) and Grommet (GR) on to the cable and strip the cable to the dimensions as shown, taking care not to nick the centre conductor or braid. Fold back the braid and slide the Top Hat (TH) onto the cable so that the tube of the Top Hat is between the dielectric and the braid (under the cable jacket). Trim off the surplus braid. Tin the centre conductor.
2) Slide the Rear Insulator (RI) over the dielectric to butt against the Top Hat. Slide the Contact (CT) onto the centre conductor so that the flange on the Contact butts against the Rear Insulator. Solder the Contact. Slide the rubber Grommet and Back Nut up to the Top Hat, trapping the braid. Slide the Front Insulator (FI) onto the Contact until it butts against the Rear Insulator.
3) Insert the cable into the body as far as possible and engage the threads of the Back Nut. Tighten the Back Nut.